MSI MS-9652 Instrukcja Użytkownika Strona 93

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 126
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 92
Report No 094061R-ITCEP07V06
Page: 90 of 123
9.6. Test Result
Product Notebook
Test Item Radiated susceptibility
Test Mode Mode 1
Date of Test 2009/04/03 Test Site Chamber5
Frequency
(MHz)
Position
(Angle)
Polarity
(H or V)
Field
Strength
(V/m)
Required
Criteria
Complied
To Criteria
(A,B,C)
Results
80-1000 FRONT H 3 A
A PASS
80-1000 FRONT V 3 A
A PASS
80-1000 BACK H 3 A
A PASS
80-1000
BACK
V 3 A A PASS
80-1000
RIGHT
H 3 A A PASS
80-1000
RIGHT
V 3 A A PASS
80-1000
LEFT
H 3 A A PASS
80-1000
LEFT
V 3 A A PASS
80-1000
UP
H 3 A A PASS
80-1000
UP
V 3 A A PASS
80-1000
DOWN
H 3 A A PASS
80-1000
DOWN
V 3 A A PASS
Note:
The testing performed is from lowest level up to the highest level as required by
standard, but only highest level is shown on the report.
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
There was no observable degradation in performance.
EUT stopped operation and could / could not be reset by operator at V/m
at frequency
MHz.
No false alarms or other malfunctions were observed during or after the test.
Przeglądanie stron 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 125 126

Komentarze do niniejszej Instrukcji

Brak uwag