MSI MS-9652 Instrukcja Użytkownika Strona 104

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 126
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 103
Report No 094061R-ITCEP07V06
Page: 101 of 123
11.6. Test Result
Product Notebook
Test Item Surge
Test Mode Mode 1
Date of Test 2009/04/02 Test Site No.2 Shielded Room
Inject
Line
Polarity Angle
Voltage
kV
Time
Interval
(Second)
Inject
Method
Required
Criteria
Complied
to
Criteria
Result
L-N
±
0 1kV 60 Direct B A PASS
L-N
±
90 1kV 60 Direct B A PASS
L-N
±
180 1kV 60 Direct B A PASS
L-N
±
270 1kV 60 Direct B A PASS
L-PE
±
0 2kV 60 Direct B A PASS
L-PE
±
90 2kV 60 Direct B A PASS
L-PE
±
180 2kV 60 Direct B A PASS
L-PE
±
270 2kV 60 Direct B A PASS
N-PE
±
0 2kV 60 Direct B A PASS
N-PE
±
90 2kV 60 Direct B A PASS
N-PE
±
180 2kV 60 Direct B A PASS
N-PE
±
270 2kV 60 Direct B A PASS
Note:
The testing performed is from lowest level up to the highest level as required by
standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test
Meet criteria B : Operate as intended after the test
Meet criteria C : Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line
.
No false alarms or other malfunctions were observed during or after the test.
Przeglądanie stron 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 125 126

Komentarze do niniejszej Instrukcji

Brak uwag