Report No: 094061R-ITCEP07V06
Page: 25 of 123
3.4. Test Procedure
The EUT and simulators are connected to the main power through a line impedance
stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
measuring equipment. The peripheral devices are also connected to the main power through
a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination.
(Please refers to the block diagram of the test setup and photographs.)
Both sides of A.C. line are checked for maximum conducted interference. In order to find the
maximum emission, the relative positions of equipment and all of the interface cables must
be changed on conducted measurement.
Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using
a receiver bandwidth of 9kHz.
3.5. Deviation from Test Standard
No deviation.