Report No.: 048L022EI
Page: 17 of 35 Version:1.0
6. Measurement Uncertainty Values
The maximum values of the absolute measurement uncertainties of the measurements defined in the
present document shall not exceed the values given below:
Parameter Uncertainty
radio frequency ± 1 x10
–5
total RF power, conducted ± 1.5 dB
RF power density, conducted ± 3 dB
spurious emissions, conducted ± 3 dB
all emissions, radiated ± 6 dB
Temperature ± 1
o
C
Humidity ± 5 %
DC and low frequency voltages ± 3 %