SUPER
USER'S MANUAL
Revision 1.0d
®
SuperServer 6026TT-HTF
SuperServer 6026TT-HTRF
SuperServer 6026TT-HIBXF
SuperServer 6026TT-HIBXRF
SuperServer 6026TT-HIBQF
SuperServer 6026TT-HIBQRF
Przeglądanie stron 0
1 2 3 4 5 6 ... 129 130

Podsumowanie treści

Strona 1 - SUPER

SUPERUSER'S MANUALRevision 1.0d®SuperServer 6026TT-HTFSuperServer 6026TT-HTRFSuperServer 6026TT-HIBXFSuperServer 6026TT-HIBXRFSuperServer 6026

Strona 2

NotesSUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL

Strona 3 - Manual Organization

7-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALAdvanced Chipset ControlThe items included in the Advanced Settings submenu are list

Strona 4

Chapter 7: BIOS7-9Patrol Scrubbing A memory error-correction scheme that works in the background looking for and correcting resident errors. The optio

Strona 5

7-10SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALAltitudeThis feature defi nes how many meters above or below sea level the system is

Strona 6 - Table of Contents

Chapter 7: BIOS7-11SouthBridge Confi gurationThis feature allows the user to confi gure the settings for the Intel ICH South Bridge chipset.USB Functio

Strona 7 - Chapter 3 System Interface

7-12SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALIDE/SATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically det

Strona 8

Chapter 7: BIOS7-13TypeSelect the type of device connected to the system. The options are Not Installed, Auto, CD/DVD and ARMD.LBA/Large ModeLBA (Logi

Strona 9 - Chapter 7 BIOS

7-14SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALDMA ModeSelect Auto to allow the BIOS to automatically detect IDE DMA mode when the

Strona 10

Chapter 7: BIOS7-1532Bit Data TransferSelect Enable to enable the function of 32-bit IDE data transfer. The options are Enabled and Disabled.IDE Detec

Strona 11 - Introduction

7-16SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALSuper IO Device Confi guration Serial Port1 Address/ Serial Port2 AddressThis option

Strona 12 - 1-2 Serverboard Features

Chapter 7: BIOS7-17VT-UTF8 Combo Key SupportA terminal keyboard defi nition that provides a way to send commands from a remote console. The options ar

Strona 13 - Infi niBand

Chapter 1 Introduction1-1 OverviewThe SuperServer 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F is a "2U Twin2" server comprised of the SC827H-(R)1400B 2U

Strona 14 - System Block Diagram

7-18SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALCPU TemperatureThe CPU thermal technology that reports absolute temperatures (Celsiu

Strona 15 - 1-3 Server Chassis Features

Chapter 7: BIOS7-19System Temperature: The system temperature will be displayed (in degrees in Celsius and Fahrenheit) as it is detected by the BIOS.

Strona 16 - Manageability Engine (ME)

7-20SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALHigh Performance Event TimerSelect Enabled to activate the High Performance Event Ti

Strona 17 - 1-5 Contacting Supermicro

Chapter 7: BIOS7-21View BMC System Event LogThis feature displays the BMC System Event Log (SEL). It shows the total number of entries of BMC System

Strona 18 - : System Notes

7-22SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALIP Address SourceSelect the source of this machine's IP address. If Static is s

Strona 19 - Server Installation

Chapter 7: BIOS7-23Subnet MaskThis item displays the current subnet mask setting for your IPMI connection.Current Subnet Mask in BMC This item display

Strona 20 - 2-4 Warnings and Precautions

7-24SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you

Strona 21 - Rack Mounting Considerations

Chapter 7: BIOS7-25Clear User Password (Available only when User Password has been set)This item allows you to clear a user password after it has been

Strona 22 - Removing the Protective Film

7-26SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALHard Disk DrivesThis feature allows the user to specify the boot sequence from all

Strona 23

Chapter 7: BIOS7-27Save Changes and ExitWhen you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility a

Strona 24

1-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL1-2 Serverboard FeaturesAt the heart of the SuperServer 6026TT-HT(R)F/HIBX(R)F/HIBQ(R

Strona 25 - Outer Rack Rails

7-28SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL7-7 BIOS RecoveryWarning! Do not upgrade the BIOS unless your system has a BIOS-re

Strona 26

Chapter 7: BIOS7-29Boot Sector Recovery from an IDE CD-ROMThis process is almost identical to the process of Boot Sector Recovery from a USB device, e

Strona 27

7-30SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL4. Power on your system and click the <Connect> button in the Hyper Terminal.

Strona 28 - 2-7 Preparing to Power On

Chapter 7: BIOS7-31c. Press <Send> to start ROM File extraction. (See the picture below.) d. Once the ROM fi le extraction is completed, the mess

Strona 29

7-32SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALNotes

Strona 30

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strona 31 - System Interface

A-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALNotes

Strona 32 - 3-4 SATA Drive Carrier LEDs

B-1Appendix C: System Specifi cationsAppendix B System Specifi cationsNote: unless noted specifi cations apply to a complete system (four serverboards).P

Strona 33 - Chapter 4

B-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALChassisSC827H-(R)1400B (2U Rackmount)Dimensions: (WxHxD) 17.2 x 3.5 x 28.5 in. (437 x

Strona 34

B-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Strona 35

Chapter 1: Introduction1-3Ethernet PortsAn Intel® network controller is integrated into each of the serverboards to support two Gigabit LAN ports (100

Strona 36 - Installation Instructions

B-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will n

Strona 37 - 250 V, 20 A

1-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALFigure 1-1. Intel 5520 Chipset:System Block DiagramNote1: This is a general block dia

Strona 38 - Power Disconnection Warning

Chapter 1: Introduction1-51-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC827H-(R)1400B 2U chassis. Detai

Strona 39 - ילמשח קותינ ינפמ הרהזא

1-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL1-4 Advanced Power Management (for -F Models Only)Intel® Intelligent Power Node Man

Strona 40 - Equipment Installation

Chapter 1: Introduction1-71-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Strona 41 - Restricted Area

1-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL1-6 2U Twin2: System NotesAs a 2U Twin2 confi guration, the SuperServer 6026TT-HT(R)F/

Strona 42 - Battery Handling

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get the SuperServer 6026TT-

Strona 43 - ﺔﻳﺭﺎﻄﺒﻟﺍ ﻝﺍﺪﺒﺘﺳﺍ

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Strona 44 - Redundant Power Supplies

2-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALChoosing a Setup Location• Leave enough clearance in front of the rack to enable you

Strona 45 - Backplane Voltage

Chapter 2: Server Installation2-3• Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. See Chapter 5 for

Strona 46 - .הדובעה

2-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALWarning: Except for short periods of time, do NOT operate the server without the cove

Strona 47 - יצראה למשחה יקוח םואית

Chapter 2: Server Installation2-52-5 Rack Mounting Instructions Warning: Do not pick up the server with the front handles. They are designed to pul

Strona 48 - רצומה קוליס

2-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALFigure 2-3. Installing the Inner Rail ExtensionsInstalling the Inner Rail ExtensionsT

Strona 49 - ﻊﺑﺎﺻﻷﺍ ﻭﻲﻏﺍﺮﺒﻟﺍ ﺕﺎﻜﻔﻣ

Chapter 2: Server Installation2-7Outer Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis e

Strona 50 - Power Cable and AC Adapter

2-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALFigure 2-5: Installing Into the RackInstalling the Chassis into a Rack1. Extend the

Strona 51 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

Chapter 2: Server Installation2-92-6 Checking the Serverboard SetupAfter you install the system in the rack, you will need to access the inside of th

Strona 52

2-10SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL2-7 Preparing to Power OnNext, you should check to make sure the SATA drives and SA

Strona 53 - Advanced Serverboard Setup

Chapter 2: Server Installation2-11Figure 2-6. Removing a Node from the System1111121211

Strona 54 - 5-3 Connecting Cables

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Strona 55 - • Control Panel cable (JF1)

2-12SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALNotes

Strona 56 - 5-4 I/O Ports

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are LEDs on the control panels and on the SATA drive carriers to keep you co

Strona 57 - Installing LGA1366 Processors

3-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL3-3 Control Panel LEDsIn addition to the LEDs built into the power and UID buttons,

Strona 58

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Strona 59 - Installing a CPU Heatsink

4-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden s

Strona 60 - Removing the Heatsink

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에

Strona 61 - 5-6 Installing Memory

4-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALInstallation Instructions Warning!Read the installation instructions before connectin

Strona 62 - CPU1 CPU2

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Strona 63

4-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALPower Disconnection Warning Warning!The system must be disconnected from all sources

Strona 64 - 5-7 Adding PCI Cards

4-7Chapter 4: Warning Statements for AC SystemsWarnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von

Strona 65 - 5-8 Serverboard Details

SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F User's ManualivChapter 3: System InterfaceRefer to this chapter for details on the system interface,

Strona 66 - LED Description

4-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALEquipment Installation Warning!Only trained and qualifi ed personnel should be allowed

Strona 67 - 5-9 Connector Defi nitions

4-9Chapter 4: Warning Statements for AC SystemsRestricted Area Warning!This unit is intended for installation in restricted access areas. A restricted

Strona 68

4-10SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALBattery Handling Warning!There is the danger of explosion if the battery is replaced

Strona 69

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Strona 70

4-12SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALRedundant Power Supplies Warning!This unit might have more than one power supply con

Strona 71

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltage Warning!Hazardous voltage or energy is present on the backplane when the system is o

Strona 72 - Pin Defi nitions

4-14SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALComply with Local and National Electrical Codes Warning!Installation of the equipmen

Strona 73 - 5-10 Jumper Settings

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Strona 74

4-16SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALWarnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen

Strona 75 - 5-11 Onboard Indicators

4-17Chapter 4: Warning Statements for AC Systems!הרהזא יקלח תא םיריסמ רשאכ שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפ

Strona 77 - 5-13 Installing Drivers

4-18SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALPower Cable and AC Adapter Warning!When installing the product, use the provided or

Strona 78 - Supero Doctor III

4-19Chapter 4: Warning Statements for AC Systems¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cabl

Strona 79

4-20SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALWaarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewe

Strona 80 - BATTERY HOLDER

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTT-H(F)/HIBX(F)/H

Strona 81 - Advanced Chassis Setup

5-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL5-2 Serverboard InstallationThis section explains the first step of physically mounti

Strona 82 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-3Connecting Data CablesThe cables used to transfer data from the peripheral devices have been carefully routed

Strona 83 - System Fan Failure

5-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi catio

Strona 84 - Overview

Chapter 5: Advanced Serverboard Setup5-51. Starting with CPU1, press the socket clip to release the load plate, which covers the CPU socket, from its

Strona 85

5-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL4. After removing the plastic cap, use your thumb and the index fi nger to hold the C

Strona 86

Chapter 5: Advanced Serverboard Setup5-71. Remove power from the system and unplug the AC power cord from the power supply.2. Do not apply any therm

Strona 87 - 6-5 Node Installation/Removal

viSUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALTable of ContentsChapter 1 Introduction1-1 Overview ...

Strona 88

5-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL1. Remove power from the system and unplug the AC power cord from the power supply.2

Strona 89 - 6-7 Power Supply

Chapter 5: Advanced Serverboard Setup5-95-6 Installing MemoryCAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any po

Strona 90

5-10SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALPopulating Memory for Optimal Performance(Single CPU Confi guration)O Branch 0 Branch

Strona 91 - Release Tab

Chapter 5: Advanced Serverboard Setup5-111.5V RDIMM Population with 5600 Processors InstalledDIMM Slots per ChannelDIMMs Populated per ChannelDIMM Typ

Strona 92

5-12SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL5-7 Adding PCI CardsPCI Express SlotThe SuperServer 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F

Strona 93 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-13Figure 5-4. X8DTT-H(F)/HIBX(F)/HIBQ(F) Series Motherboard Layout5-8 Serverboard DetailsJF1LE4SW1J18JWR2JWR1FA

Strona 94 - 7-2 Main Setup

5-14SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALX8DTT-H(F)/HIBX(F)/HIBQ(F) Quick ReferenceJumper Description Default SettingJBMC1 BM

Strona 95

Chapter 5: Advanced Serverboard Setup5-15Reset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the

Strona 96 - BOOT Features

5-16SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALNIC2 (LAN2) LEDThe LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN

Strona 97 - Power Confi guration

Chapter 5: Advanced Serverboard Setup5-17HDD LEDThe HDD LED and UID switch connections are located on pins 13 and 14 of JF1. Attach a hard drive LED c

Strona 98 - Processor and Clock Options

viiTable of ContentsReduced Airfl ow ... 2-3Mechanical Loading ..

Strona 99

5-18SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALSerial PortsOne serial port is included on the serverboard. The COM1 port is located

Strona 100 - CPU Bridge Confi guration

Chapter 5: Advanced Serverboard Setup5-19I2C Power ConnectorThis header is for I2C, which may be used to monitor the status of the power supply, fan a

Strona 101

5-20SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALWake-On-LAN (JWOL1)Pin Defi nitionsPin# Defi nition1 +5V Standby2 Ground3 Wake-upWa

Strona 102 - North Bridge Confi guration

Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consi

Strona 103 - SouthBridge Confi guration

5-22SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALBMC Enable/Disable (JPBMC1)Jumper SettingsBoth Jumpers Defi nitionPins 1-2 Enable

Strona 104 - IDE/SATA Confi guration

Chapter 5: Advanced Serverboard Setup5-23LAN1/LAN2 LEDsThe Ethernet ports (located beside the COM port) have two LEDs. On each Gb LAN port, one LED in

Strona 105

5-24SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALInfi niBand Link LED (LEB1)Indicator SettingsColor Status Defi nition

Strona 106

Chapter 5: Advanced Serverboard Setup5-25Figure 5-5. Driver/Tool Installation Display Screen5-13 Installing DriversThe CD that came bundled with the s

Strona 107 - PCI/PnP Confi guration

5-26SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALSupero Doctor IIIThe SuperDoctor® III program is a Web base management tool that sup

Strona 108 - Remote Access Confi guration

Chapter 5: Advanced Serverboard Setup5-27Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://

Strona 109 - Hardware Health Monitor

viiiSUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALChapter 5 Advanced Serverboard Setup5-1 Handling the Serverboard ...

Strona 110

5-28SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL5-14 Serverboard BatteryCaution: There is a danger of explosion if the onboard batte

Strona 111 - ACPI Confi guration

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Strona 112 - General WHEA Confi guration

6-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUAL6-2 Control PanelEach control panel on the front of the chassis must be connected to

Strona 113 - IP Address Confi guration

Chapter 6: Advanced Chassis Setup6-3Fan Confi gurationIn the 2U Twin2, each node (serverboard) controls the two fans that reside on its side of the cha

Strona 114 - Subnet Mask Confi guration

6-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALFigure 6-3. Removing a Dummy Drive Tray11116-4 Hard Drive Installation/RemovalOvervi

Strona 115 - DMI Event Log

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Hard Drive in a CarrierDrive TrayHard Drive1212Mounting a Hard Drive in a Carrier1. Instal

Strona 116 - 7-4 Security Settings

6-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALInstalling/Removing Hot-swap Drives1. To remove a carrier, push the release button l

Strona 117 - 7-5 Boot Confi guration

Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Drives and Nodes: Logical Confi guration1B1A1C1DNode ANode BNode CNode D6-5 Node Installation/RemovalAs

Strona 118 - • 2nd Drive

6-8SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALFigure 6-7. Removing a System Node1212131312

Strona 119

Chapter 6: Advanced Chassis Setup6-96-6 Installing the Air ShroudsAir ShroudsAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC827 ch

Strona 120 - 7-7 BIOS Recovery

Air Shrouds ... 6-96-7 Power Supply ...

Strona 121 - Requirements

6-10SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALPower Supply Failure: Redundant Power (Two Modules)The SuperServer 6026TT-HTRF, 6026

Strona 122 - Starting remote flash

Chapter 6: Advanced Chassis Setup6-11Release TabFigure 6-8. Removing the Power Supply

Strona 123

6-12SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALNotes

Strona 124

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the SuperServer 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F

Strona 125 - BIOS Error Beep Codes

7-2SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routin

Strona 126

Chapter 7: BIOS7-3System OverviewThe following BIOS information will be displayed:System Time/System Date Use this option to change the system time an

Strona 127 - System Specifi cations

7-4SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALSystem Memory This displays the size of memory available in the system:SizeThis item

Strona 128

Chapter 7: BIOS7-5Bootup Num-LockThis feature selects the Power-on state for Numlock key. The options are Off and On.Wait For 'F1' If ErrorT

Strona 129 - Regulatory Compliance

7-6SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F USER'S MANUALProcessor and Clock OptionsThis submenu allows the user to confi gure the Processor a

Strona 130

Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Simultaneous Multi-Threading Technology,

Komentarze do niniejszej Instrukcji

Brak uwag