Report No: 088213R-ITCEP07V04
Page: 24 of 131
2.4. Test Environment
Performed Item Items Required Actual
Temperature (C)
15-35 25
Conducted Emission Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 25
Impedance Stabilization
Network
Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 25
Radiated Emission Humidity (%RH) 25-75 50
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 21
Electrostatic Discharge Humidity (%RH) 30-60 52
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Radiated susceptibility Humidity (%RH) 25-75 52
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Electrical fast
transient/burst
Humidity (%RH) 25-75 53
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Surge Humidity (%RH) 10-75 53
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Conducted susceptibility Humidity (%RH) 25-75 52
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Power frequency
magnetic field
Humidity (%RH) 25-75 53
Barometric pressure (mbar) 860-1060 950-1000
Temperature (C)
15-35 22
Voltage dips and
interruption
Humidity (%RH) 25-75 53
Barometric pressure (mbar) 860-1060 950-1000
Komentarze do niniejszej Instrukcji